Mono HSF Booster Set

Mono HSF Booster Set
Variable Frequency Constant Pressure Booster – ASG Pump

Specifications:
Mono ASG Close Coupled Pump
• Material for all Wet Parts: SS304 or SS316
• Capacity: 3-72 m3/hr
• Head: 6-55M
• Max Working Pressure: 10 Bar
• Liquid Temp Range: -15°C- 110°C
• Motor
▪▪ Power Supply: 3x220/380V, 50hz
▪▪ TEFC, IP55, F Class,
▪▪ Horsepower: 0.75kw-7.5kw
▪▪ Noise: 60dBA

 
Functions :
• Constant Pressure control by frequency converter
• Quiet and Non Water Hammer operation. Built in PI control function to control the pump in soft start and stop to prevent water hammer; to control the speed increase and decrease gradually to prevent the noise in sudden speed change
• System Stop automatically when no use of water. When the system detect no use of water, motor will reduce the speed in 10%, after 10sec, the system will stop the pump operation
• Dry Running Protection. When the pump running in full speed, but the pressure is still 50% under setting point After 30sec, the system will shut down the power to prevent the damage of pump. Need to reset the system, then the pump can be restarted in 10sec.
• Motor Protection Functions: High / Low voltage; Over current, Overloading; Overheating; phase failure; grounding failure.
 
Material Specifications:
• Frequency Converter: Danfoss or Equivalent
• HY-PO: Japanese Controller
• Pressure Transmitter: Danfoss: 0-10 Bar or 4-20mA
• Pressure Tank: IPP Diaphragm Tank
• Pipes, fittings and 5 way Valve with non-return valve: SS304
• Control Panel: 2.5mm thick steel plate with powdered painting
 
 
Dimensions
 
 
 

 
2 MXF Booster Set

2 MXF Booster Set
Variable Frequency Constant – 2x MHE Pump
50HZ

Specifications:
Two units of MHE Pump
• Material for all wet parts: SS304
• Applications: Domestic Water Supply, Commercial use such as barber shop, motel, restaurant etc.
• Product Specifications:

▪▪ Capacity:
▪▪ Head:
▪▪ Max Working Pressure: 8 Bar
▪▪ Motor:
♦ Single Phase: 1x220V, 50hz
♦ Three Phase: 2x220/380V, 50hz
♦ Output Power: 0.37kw-0.75kw
♦ Insulation: F Class
♦ Protection Class: IP55
♦ Noise< 60dBA

 
Functions :
• Alternative parallel
• Constant Pressure control by frequency converter
• Quiet and Non Water Hammer operation. Built in PI control function to control the pump in soft start and stop to prevent water hammer; to control the speed increase and decrease gradually to prevent the noise in sudden speed change
• System Stop automatically when no use of water. When the system detect no use of water, motor will reduce the speed in 10%, after 10sec, the system will stop the pump operation
• Dry Running Protection. When the pump running in full speed, but the pressure is still 50% under setting point. After 30sec, the system will shut down the power to prevent the damage of pump. Need to reset the system, then the pump can be restarted in 10sec.
• Alternative fault
• Alternative timing
• Built in RS-232 and RS-485 Communication Protocol
• Panel Display to display the failure signal for trouble shooting
• Motor Protection Functions: High / Low voltage; Over current, Overloading; Overheating; phase failure; grounding failure.
 
 
 
 
 

 
2 VMF Booster Set

2 VMF Booster Set
Variable Frequency Constant – 2x MVI Pump

Specifications:
Two units of MVI Vertical Multistage Pump

• Material for all Wet Parts: SS304 or SS316
• Capacity: 2-24 m3/hr
• Head: 13-224M
• Max Working Pressure: 25 Bar
• Liquid Temp Range: -15°C- 120°C
• Power Supply: 3x220/380V, 50hz
• Motor:
▪ TEFC, IP55, F Class,
▪ Horsepower: 0.75kw-7.5kw

 
Functions:
• Alternative parallel
• Constant Pressure control by frequency converter
• Quiet and Non Water Hammer operation. Built in PI control function to control the pump in soft start and stop to prevent water hammer; to control the speed increase and decrease gradually to prevent the noise in sudden speed change
• System Stop automatically when no use of water. When the system detect no use of water, motor will reduce the speed in 10%, after 10sec, the system will stop the pump operation
• Dry Running Protection. When the pump running in full speed, but the pressure is still 50% under setting point. After 30sec, the system will shut down the power to prevent the damage of pump. Need to reset the system, then the pump can be restarted in 10sec.
• Alternative fault
• Alternative timing
• Built in RS-232 and RS-485 Communication Protocol
• Panel Display to display the failure signal for trouble shooting
• Motor Protection Functions: High / Low voltage; Over current, Overloading; Overheating; phase failure; grounding failure.
 